Cooney Brothers
Home

Products

Products

Apollo™ 4ALF60EE7

Apollo™ 4ALF60EE7 DCDALF4A Type 1 Backflow Preventer With 1/2 in Double Check Bypass Sub-Assembly, 8 in Nominal, Outside Stem and Yoke Flanged x Outside Stem and Yoke Groove End Style, 304 Stainless Steel Body, Dual Check, Domestic

CBPN:247173

UPC:670750554506

MPN:4ALF60EE7

Price:
$9161.22 / EA
Oversize or overweight
This item cannot ship via small package carrier, such as UPS or FedEx Ground. Delivery options will be available at checkout.
Prop 65:

DESCRIPTION

Apollo™ Backflow Preventer, Type 1, Series: DCDALF4A, 8 in Nominal, Outside Stem and Yoke Flanged x Outside Stem and Yoke Groove, 175 psi, 33 to 140 deg F, Dual Check Backflow, Media: Water, 304 Stainless Steel Body, Domestic

The 2-1/2 in to 12 in Double Check Detector Assembly shall be an Apollo™ Model DCDALF 4A or DCDA2LF 4A. The assembly shall be manufactured in America and carry a 5-year Apollo™ factory warranty. The TriForce™ center-stem guided check valves shall feature reversible silicone rubber seat discs. The check valves shall be held in place by stainless steel snap-in retainers (2-1/2 in to 6 in) or stainless steel studs and nuts (8 in to 12 in). Access to the check valves shall be by an Apollo™ quick-connect stainless steel coupling (2-1/2 in to 6 in) or grooved couplings (8 in to 12 in). The bodies shall be domestic stainless steel in 22-1/2 in to 8 in sizes and FDA epoxy-coated ductile iron in 10 in and 12 in sizes. The assembly consists of a mainline double check valve with a Type 2 bypass (Type 1 optional) consisting of a lead free single check (SCV) and meter bypassing the mainline second check to prevent backflow while accurately measuring all flows up to 2 gpm while the mainline 2nd check remains closed. Assemblies with the optional Type 1 bypass consist of a lead free double check valve and meter which bypass both mainline checks and accurately meter all flows up to 2 gpm with the mainline checks closed. The Apollo™ lead free domestic ball valve test cocks shall have stainless steel handles. The pressure drop across the assembly shall be documented by an independent laboratory. The assembly shall prevent contamination of the potable water supply due to back-siphonage or backpressure from substances that are non-health hazards.

Apollo™ 4ALF60EE7 DCDALF4A Type 1 Backflow Preventer With 1/2 in Double Check Bypass Sub-Assembly, 8 in Nominal, Outside Stem and Yoke Flanged x Outside Stem and Yoke Groove End Style, 304 Stainless Steel Body, Dual Check, Domestic

CBPN:247173

MPN:4ALF60EE7

UPC:670750554506

Price:
$9161.22 / EA
Oversize or overweight
This item cannot ship via small package carrier, such as UPS or FedEx Ground. Delivery options will be available at checkout.
 
Prop 65:
Apollo Valve Logo

DESCRIPTION

Apollo™ Backflow Preventer, Type 1, Series: DCDALF4A, 8 in Nominal, Outside Stem and Yoke Flanged x Outside Stem and Yoke Groove, 175 psi, 33 to 140 deg F, Dual Check Backflow, Media: Water, 304 Stainless Steel Body, Domestic

The 2-1/2 in to 12 in Double Check Detector Assembly shall be an Apollo™ Model DCDALF 4A or DCDA2LF 4A. The assembly shall be manufactured in America and carry a 5-year Apollo™ factory warranty. The TriForce™ center-stem guided check valves shall feature reversible silicone rubber seat discs. The check valves shall be held in place by stainless steel snap-in retainers (2-1/2 in to 6 in) or stainless steel studs and nuts (8 in to 12 in). Access to the check valves shall be by an Apollo™ quick-connect stainless steel coupling (2-1/2 in to 6 in) or grooved couplings (8 in to 12 in). The bodies shall be domestic stainless steel in 22-1/2 in to 8 in sizes and FDA epoxy-coated ductile iron in 10 in and 12 in sizes. The assembly consists of a mainline double check valve with a Type 2 bypass (Type 1 optional) consisting of a lead free single check (SCV) and meter bypassing the mainline second check to prevent backflow while accurately measuring all flows up to 2 gpm while the mainline 2nd check remains closed. Assemblies with the optional Type 1 bypass consist of a lead free double check valve and meter which bypass both mainline checks and accurately meter all flows up to 2 gpm with the mainline checks closed. The Apollo™ lead free domestic ball valve test cocks shall have stainless steel handles. The pressure drop across the assembly shall be documented by an independent laboratory. The assembly shall prevent contamination of the potable water supply due to back-siphonage or backpressure from substances that are non-health hazards.

Specifications

BrandApollo™
Body Material304 Stainless Steel
Domestic/ImportDomestic
End StyleOutside Stem and Yoke Flanged x Outside Stem and Yoke Groove
Nominal Size8 in
Pressure Rating175 psi
SeriesDCDALF4A
Temperature Rating33 to 140 deg F
TypeType 1
MediaWater
Backflow TypeDual Check
Weight727 lbs

Item Features

  • Easy maintenance no special tools required
  • Low pressure loss as documented by an independent laboratory
  • Center-stem guided Triforce™ check valves
  • Bolted-In checks
  • Meter type - gpm
  • Lead free - The wetted surfaces of this product shall contain no more than 0.25% lead by weighted average, complies with Federal Public Law 111-380, ANSI 3rd party approved and listed