Cooney Brothers
Home

Products

Products

Apollo™ 4ALF21A02

Apollo™ 4ALF21A02 RPLF4A Principle Backflow Preventer With Y-Strainer, 4 in, Non-Rising Stem Flanged, 304 Stainless Steel Body, Reduced Pressure, Domestic

CBPN:247092

UPC:670750780134

MPN:4ALF21A02

Price:
$3714.80 / ea
Availability Information
Oversize or overweight
This item cannot ship via small package carrier, such as UPS or FedEx Ground. Delivery options will be available at checkout.
Prop 65:

DESCRIPTION

Apollo™ Principle Backflow Preventer, Series: RPLF4A, 4 in Nominal, Non-Rising Stem Flanged, 175 psi, 33 to 140 deg F, Reduced Pressure Backflow, 304 Stainless Steel Body, Domestic

The Apollo™ Model RPLF 4A Reduced Pressure Principle Backflow Preventers consist of two independently acting, TriForce™ center stem guided check valves with a differential pressure relief valve located between the check valves. The unit is designed to give maximum protection against backflow of health or non-health hazard fluids by either back-pressure or back-siphonage. The durable domestic stainless steel units (2-1/2 in - 8 in) and the FDA epoxy coated ductile iron units (10 in and 12 in) are easily maintained in the line without any special tools. The TriForce™ check valves operate with a spring assist in the flowing condition to provide excellent flow rates which are documented by an independent laboratory.

Apollo™ 4ALF21A02 RPLF4A Principle Backflow Preventer With Y-Strainer, 4 in, Non-Rising Stem Flanged, 304 Stainless Steel Body, Reduced Pressure, Domestic

CBPN:247092

MPN:4ALF21A02

UPC:670750780134

Price:
$3714.80 / ea
Availability Information
Oversize or overweight
This item cannot ship via small package carrier, such as UPS or FedEx Ground. Delivery options will be available at checkout.
 
Prop 65:
Apollo Valve Logo

DESCRIPTION

Apollo™ Principle Backflow Preventer, Series: RPLF4A, 4 in Nominal, Non-Rising Stem Flanged, 175 psi, 33 to 140 deg F, Reduced Pressure Backflow, 304 Stainless Steel Body, Domestic

The Apollo™ Model RPLF 4A Reduced Pressure Principle Backflow Preventers consist of two independently acting, TriForce™ center stem guided check valves with a differential pressure relief valve located between the check valves. The unit is designed to give maximum protection against backflow of health or non-health hazard fluids by either back-pressure or back-siphonage. The durable domestic stainless steel units (2-1/2 in - 8 in) and the FDA epoxy coated ductile iron units (10 in and 12 in) are easily maintained in the line without any special tools. The TriForce™ check valves operate with a spring assist in the flowing condition to provide excellent flow rates which are documented by an independent laboratory.

Specifications

BrandApollo™
Body Material304 Stainless Steel
Domestic/ImportDomestic
End StyleNon-Rising Stem Flange
Nominal Size4 in
Pressure Rating175 psi
SeriesRPLF4A
Temperature Rating33 to 140 deg F
Backflow TypeReduced Pressure

Item Features

  • Easy maintenance no special tools required
  • Low pressure loss as documented by an independent laboratory
  • Center-stem guided TriForce™ check valves
  • Approved for horizontal flow
  • Snap-in check retainers
  • Lead free - The wetted surfaces of this product shall contain no more than 0.25% lead by weighted average, complies with Federal Public Law 111-380, ANSI 3rd party approved and listed