Cooney Brothers
Home
Home
Apollo™ 4ALF21002

Apollo™ 4ALF21002 RPLF4A Principle Backflow Preventer With Y-Strainer, 3 in, Non-Rising Stem Flanged, 304 Stainless Steel Body, Reduced Pressure, Domestic

CBPN: 247089

UPC:670750780226

MPN:4ALF21002

Price:
$5239.02 / EA
Oversize or overweight
This item cannot ship via small package carrier, such as UPS or FedEx Ground. Delivery options will be available at checkout.
Prop 65:

DESCRIPTION

Apollo™ 4ALF21002, Principle Backflow Preventer, Standard, Series: RPLF4A, 3 in Nominal, Non-Rising Stem Flange End Style, 175 psi Pressure, 33 to 180 deg F, Reduced Pressure Backflow, Full Port, Bronze Body, Domestic

The Apollo™ Model RPLF 4A Reduced Pressure Principle Backflow Preventers consist of two independently acting, TriForce™ center stem guided check valves with a differential pressure relief valve located between the check valves. The unit is designed to give maximum protection against backflow of health or non-health hazard fluids by either back-pressure or back-siphonage. The durable domestic stainless steel units (2-1/2 in - 8 in) and the FDA epoxy coated ductile iron units (10 in and 12 in) are easily maintained in the line without any special tools. The TriForce™ check valves operate with a spring assist in the flowing condition to provide excellent flow rates which are documented by an independent laboratory.

Apollo™ 4ALF21002 RPLF4A Principle Backflow Preventer With Y-Strainer, 3 in, Non-Rising Stem Flanged, 304 Stainless Steel Body, Reduced Pressure, Domestic

CBPN: 247089

MPN:4ALF21002

UPC:670750780226

Price:
$5239.02 / EA
Oversize or overweight
This item cannot ship via small package carrier, such as UPS or FedEx Ground. Delivery options will be available at checkout.
 
Prop 65:
Apollo Valve Logo

DESCRIPTION

Apollo™ 4ALF21002, Principle Backflow Preventer, Standard, Series: RPLF4A, 3 in Nominal, Non-Rising Stem Flange End Style, 175 psi Pressure, 33 to 180 deg F, Reduced Pressure Backflow, Full Port, Bronze Body, Domestic

The Apollo™ Model RPLF 4A Reduced Pressure Principle Backflow Preventers consist of two independently acting, TriForce™ center stem guided check valves with a differential pressure relief valve located between the check valves. The unit is designed to give maximum protection against backflow of health or non-health hazard fluids by either back-pressure or back-siphonage. The durable domestic stainless steel units (2-1/2 in - 8 in) and the FDA epoxy coated ductile iron units (10 in and 12 in) are easily maintained in the line without any special tools. The TriForce™ check valves operate with a spring assist in the flowing condition to provide excellent flow rates which are documented by an independent laboratory.

Specifications

BrandApollo™
Weight153 lbs
Nominal Size3 in
End StyleNon-Rising Stem Flange
Body MaterialBronze
Backflow TypeReduced Pressure
Manufacturer NameApollo Conbraco
Port TypeFull
Pressure Rating175 psi
SeriesRPLF4A
Temperature Rating33 to 180 deg F
TypeStandard
ApplicationHorizontal Flow
Warranty5 Years
Domestic/ImportDomestic
Country of OriginUS
Standards and ApprovalsARRA Compliant | ASSE 1013 | Approved by the Foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California | AWWA C511 | ASSE 1013-2011 | CSA B64.4 | FM Approved | IAPMO Listed | UL/cUL Listed | US Patents 6443184/7025085/7533699/8240333 | US FCCCHR | NSF 372 | PROP65: Cancer and Reproductive Harm

Item Features

  • Easy maintenance no special tools required
  • Low pressure loss as documented by an independent laboratory
  • Center-stem guided TriForce check valves
  • Approved for horizontal flow
  • Snap-in check retainers