Apollo RPLF4A Backflow Preventer with OSY Grooved Shut-off Valves

Apollo™ 4ALF20C08 RPLF4A Standard Principle Backflow Preventer, 6 in Nominal, Outside Stem and Yoke Groove End Style, Bronze Body, Reduced Pressure, Domestic

CBPN: 247083

UPC:670750550553

MPN:4ALF20C08

Apollo™ 4ALF20C08 has been discontinued by the manufacturer.
Oversize or overweight
This item cannot ship via small package carrier, such as UPS or FedEx Ground. Delivery options will be available at checkout.
Prop 65:

DESCRIPTION

Apollo™ 4ALF20C08, Principle Backflow Preventer, Standard, Series: RPLF4A, 6 in Nominal, Outside Stem and Yoke Groove End Style, 175 psi Pressure, 33 to 180 deg F, Reduced Pressure Backflow, Full Port, Bronze Body, Domestic

The Apollo™ Model RPLF 4A Reduced Pressure Principle Backflow Preventers consist of two independently acting, TriForce™ center stem guided check valves with a differential pressure relief valve located between the check valves. The unit is designed to give maximum protection against backflow of health or non-health hazard fluids by either back-pressure or back-siphonage. The durable domestic stainless steel units (2-1/2 in - 8 in) and the FDA epoxy coated ductile iron units (10 in and 12 in) are easily maintained in the line without any special tools. The TriForce™ check valves operate with a spring assist in the flowing condition to provide excellent flow rates which are documented by an independent laboratory.

Apollo™ 4ALF20C08 RPLF4A Standard Principle Backflow Preventer, 6 in Nominal, Outside Stem and Yoke Groove End Style, Bronze Body, Reduced Pressure, Domestic

CBPN: 247083

MPN:4ALF20C08

UPC:670750550553

Apollo™ 4ALF20C08 has been discontinued by the manufacturer.
Oversize or overweight
This item cannot ship via small package carrier, such as UPS or FedEx Ground. Delivery options will be available at checkout.
 
Prop 65:
Apollo Valve Logo

DESCRIPTION

Apollo™ 4ALF20C08, Principle Backflow Preventer, Standard, Series: RPLF4A, 6 in Nominal, Outside Stem and Yoke Groove End Style, 175 psi Pressure, 33 to 180 deg F, Reduced Pressure Backflow, Full Port, Bronze Body, Domestic

The Apollo™ Model RPLF 4A Reduced Pressure Principle Backflow Preventers consist of two independently acting, TriForce™ center stem guided check valves with a differential pressure relief valve located between the check valves. The unit is designed to give maximum protection against backflow of health or non-health hazard fluids by either back-pressure or back-siphonage. The durable domestic stainless steel units (2-1/2 in - 8 in) and the FDA epoxy coated ductile iron units (10 in and 12 in) are easily maintained in the line without any special tools. The TriForce™ check valves operate with a spring assist in the flowing condition to provide excellent flow rates which are documented by an independent laboratory.

Specifications

Brand: Apollo™
Weight: 385 lbs
Nominal Size: 6 in
End Style: Outside Stem and Yoke Groove
Body Material: Bronze
Backflow Type: Reduced Pressure
Manufacturer Name: Apollo Conbraco
Port Type: Full
Pressure Rating: 175 psi
Series: RPLF4A
Temperature Rating: 33 to 180 deg F
Type: Standard
Application: Horizontal Flow
Warranty: 5 Years
Domestic/Import: Domestic
Country of Origin: US
Standards and Approvals: ARRA Compliant | ASSE 1013 | Approved by the Foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California | AWWA C511 | ASSE 1013-2011 | CSA B64.4 | FM Approved | IAPMO Listed | UL/cUL Listed | US Patents 6443184/7025085/7533699/8240333 | US FCCCHR | NSF 372 | PROP65: Cancer and Reproductive Harm

Item Features

  • Easy maintenance no special tools required
  • Low pressure loss as documented by an independent laboratory
  • Center-stem guided TriForce check valves
  • Approved for horizontal flow
  • Snap-in check retainers