Apollo™ 4ALF209012 RPLF4A Standard Principle Backflow Preventer, 2-1/2 in Nominal, Non-Rising Stem Flanged x Non-Rising Stem Groove End Style, Bronze Body, Reduced Pressure, Domestic
CBPN: 247078
UPC:670750669798
MPN:4ALF209012
DESCRIPTION
Apollo™ 4ALF209012, Principle Backflow Preventer, Standard, Series: RPLF4A, 2-1/2 in Nominal, Non-Rising Stem Flanged x Non-Rising Stem Groove End Style, 175 psi Pressure, 33 to 180 deg F, Reduced Pressure Backflow, Full Port, Bronze Body, Domestic
The Apollo™ Model RPLF 4A Reduced Pressure Principle Backflow Preventers consist of two independently acting, TriForce™ center stem guided check valves with a differential pressure relief valve located between the check valves. The unit is designed to give maximum protection against backflow of health or non-health hazard fluids by either back-pressure or back-siphonage. The durable domestic stainless steel units (2-1/2 in - 8 in) and the FDA epoxy coated ductile iron units (10 in and 12 in) are easily maintained in the line without any special tools. The TriForce™ check valves operate with a spring assist in the flowing condition to provide excellent flow rates which are documented by an independent laboratory.
Apollo™ 4ALF209012 RPLF4A Standard Principle Backflow Preventer, 2-1/2 in Nominal, Non-Rising Stem Flanged x Non-Rising Stem Groove End Style, Bronze Body, Reduced Pressure, Domestic
CBPN: 247078
MPN:4ALF209012
UPC:670750669798
DESCRIPTION
Apollo™ 4ALF209012, Principle Backflow Preventer, Standard, Series: RPLF4A, 2-1/2 in Nominal, Non-Rising Stem Flanged x Non-Rising Stem Groove End Style, 175 psi Pressure, 33 to 180 deg F, Reduced Pressure Backflow, Full Port, Bronze Body, Domestic
The Apollo™ Model RPLF 4A Reduced Pressure Principle Backflow Preventers consist of two independently acting, TriForce™ center stem guided check valves with a differential pressure relief valve located between the check valves. The unit is designed to give maximum protection against backflow of health or non-health hazard fluids by either back-pressure or back-siphonage. The durable domestic stainless steel units (2-1/2 in - 8 in) and the FDA epoxy coated ductile iron units (10 in and 12 in) are easily maintained in the line without any special tools. The TriForce™ check valves operate with a spring assist in the flowing condition to provide excellent flow rates which are documented by an independent laboratory.
Specifications
Item Features
- Easy maintenance no special tools required
- Low pressure loss as documented by an independent laboratory
- Center-stem guided TriForce check valves
- Approved for horizontal flow
- Snap-in check retainers
Similar Items

Apollo™ 4ALF20909 RPLF4A Standard Principle Backflow Preventer, 2-1/2 in Nominal, Monitored Butterfly Valve Groove End Style, Bronze Body, Reduced Pressure, Domestic
CBPN:
247079
MPN:
4ALF20909

Apollo™ 4ALF20903 RPLF4A Standard Principle Backflow Preventer, 2-1/2 in Nominal, Outside Stem and Yoke Flanged End Style, Bronze Body, Reduced Pressure, Domestic
CBPN:
182034
MPN:
4ALF20903

Apollo™ 4ALF20902 4ALF-200 LBF Backflow Preventer, 2-1/2 in Nominal, NRS Flanged End Style, 304 Stainless Steel Body, Reduced Pressure, Domestic
CBPN:
179009
MPN:
4ALF20902