DESCRIPTION

Apollo™ 4ALF10E01, Backflow Preventer, Standard, Series: DCLF4A, 8 in Nominal, 175 psi Pressure, 33 to 140 deg F, Dual Check Backflow, Media: Water, 304 Stainless Steel Body, Domestic

The 2-1/2 in to 12 in Backflow Preventer shall be an Apollo™ Model DCLF 4A Lead Free Double Check Valve. The assembly shall be manufactured in America and carry a 5-year Apollo™ factory warranty. The TriForce™ center stem guided check valves shall feature reversible silicone rubber seat discs. The check valves shall be held in place by stainless steel snap-in retainers (2-1/2 in to 6 in) or stainless steel studs & nuts (8 in to 12 in). Access to the check valves shall be by an Apollo™ quick-connect stainless steel coupling (2-1/2 in to 6 in) or grooved couplings (8 in to 12 in). The bodies shall be domestic stainless steel in 2-1/2 in to 8 in sizes and FDA epoxy coated ductile iron in 10 in & 12 in sizes. The lead free Apollo™ domestic ball valve test cocks shall have stainless steel handles. The assembly shall prevent contamination of the potable water supply due to back-siphonage or backpressure from substances that are non-health hazards. The pressure drop across the assembly shall be documented by an independent laboratory.

Apollo™ 4ALF10E01 DCLF4A Standard Backflow Preventer, 8 in Nominal, 304 Stainless Steel Body, Dual Check, Domestic

CBPN: 245708

MPN:4ALF10E01

UPC:670750715983

Apollo™ 4ALF10E01 has been discontinued by the manufacturer.
Oversize or overweight
This item cannot ship via small package carrier, such as UPS or FedEx Ground. Delivery options will be available at checkout.
 
Prop 65:
Apollo Valve Logo

DESCRIPTION

Apollo™ 4ALF10E01, Backflow Preventer, Standard, Series: DCLF4A, 8 in Nominal, 175 psi Pressure, 33 to 140 deg F, Dual Check Backflow, Media: Water, 304 Stainless Steel Body, Domestic

The 2-1/2 in to 12 in Backflow Preventer shall be an Apollo™ Model DCLF 4A Lead Free Double Check Valve. The assembly shall be manufactured in America and carry a 5-year Apollo™ factory warranty. The TriForce™ center stem guided check valves shall feature reversible silicone rubber seat discs. The check valves shall be held in place by stainless steel snap-in retainers (2-1/2 in to 6 in) or stainless steel studs & nuts (8 in to 12 in). Access to the check valves shall be by an Apollo™ quick-connect stainless steel coupling (2-1/2 in to 6 in) or grooved couplings (8 in to 12 in). The bodies shall be domestic stainless steel in 2-1/2 in to 8 in sizes and FDA epoxy coated ductile iron in 10 in & 12 in sizes. The lead free Apollo™ domestic ball valve test cocks shall have stainless steel handles. The assembly shall prevent contamination of the potable water supply due to back-siphonage or backpressure from substances that are non-health hazards. The pressure drop across the assembly shall be documented by an independent laboratory.

Specifications

Brand: Apollo™
Weight: 208 lbs
Nominal Size: 8 in
Body Material: 304 Stainless Steel
Backflow Type: Dual Check
Manufacturer Name: Apollo Conbraco
Media: Water
Pressure Rating: 175 psi
Series: DCLF4A
Temperature Rating: 33 to 140 deg F
Type: Standard
Application: Horizontal and vertical up flow
Warranty: 5 Years
Domestic/Import: Domestic
Country of Origin: US
Standards and Approvals: ARRA Compliant | ASSE 1015-2011 | Approved by the Foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California | AWWA C511 | CSA B64.4 | FM Approved | TL Certified | IAPMO Listed | USC FCCCHR | UL/cUL Listed | US Patents 6443184/7025085/7533699 | US FCCCHR | NSF/ANSI 372 | PROP65: Cancer and Reproductive Harm

Item Features

  • Easy maintenance no special tools required
  • Low pressure loss as documented by an independent laboratory
  • Center-stem guided TriForce check valves
  • Approved for horizontal and vertical up flow
  • Chloramine-resistant elastomers
  • Bolted-in checks
  • Less Shut-off valve