Apollo Model RPLF 4A Reduced Pressure Principle Backflow Preventer

Apollo™ 4ALF21903 4ALF-200 LBF Backflow Preventer, 2-1/2 in Nominal, OSY Flanged End Style, 304 Stainless Steel Body, Reduced Pressure, Domestic

CBPN: 247091

UPC:670750780127

MPN:4ALF21903

Price:
$5185.27 / EA
Oversize or overweight
This item cannot ship via small package carrier, such as UPS or FedEx Ground. Delivery options will be available at checkout.
Prop 65:

DESCRIPTION

Apollo™ 4ALF21903, Backflow Preventer, Series: 4ALF-200 LBF, 2-1/2 in Nominal, OSY Flanged End Style, 175 psi Pressure, 33 to 140 deg F, Reduced Pressure Backflow, 304 Stainless Steel Body, Domestic

The Apollo™ MODEL RPLF 4A Reduced Pressure Principle Backflow Preventers consist of two independently acting, TriForce™ center stem guided check valves with a differential pressure relief valve located between the check valves. The unit is designed to give maximum protection against backflow of health or non-health hazard fluids by either back-pressure or backsiphonage. The durable domestic stainless steel units (2-1/2 to 8 in) and the FDA epoxy coated ductile iron units (10 and 12 in) are easily maintained in the line without any special tools. The TriForce™ check valves operate with a spring assist in the flowing condition to provide excellent flow rates which are documented by an independent laboratory.

Apollo™ 4ALF21903 4ALF-200 LBF Backflow Preventer, 2-1/2 in Nominal, OSY Flanged End Style, 304 Stainless Steel Body, Reduced Pressure, Domestic

CBPN: 247091

MPN:4ALF21903

UPC:670750780127

Price:
$5185.27 / EA
Oversize or overweight
This item cannot ship via small package carrier, such as UPS or FedEx Ground. Delivery options will be available at checkout.
 
Prop 65:
Apollo Valve Logo

DESCRIPTION

Apollo™ 4ALF21903, Backflow Preventer, Series: 4ALF-200 LBF, 2-1/2 in Nominal, OSY Flanged End Style, 175 psi Pressure, 33 to 140 deg F, Reduced Pressure Backflow, 304 Stainless Steel Body, Domestic

The Apollo™ MODEL RPLF 4A Reduced Pressure Principle Backflow Preventers consist of two independently acting, TriForce™ center stem guided check valves with a differential pressure relief valve located between the check valves. The unit is designed to give maximum protection against backflow of health or non-health hazard fluids by either back-pressure or backsiphonage. The durable domestic stainless steel units (2-1/2 to 8 in) and the FDA epoxy coated ductile iron units (10 and 12 in) are easily maintained in the line without any special tools. The TriForce™ check valves operate with a spring assist in the flowing condition to provide excellent flow rates which are documented by an independent laboratory.

Specifications

BrandApollo™
Weight142 lbs
Nominal Size2-1/2 in
End StyleOSY Flanged
Body Material304 Stainless Steel
Backflow TypeReduced Pressure
Manufacturer NameApollo Conbraco
Pressure Rating175 psi
Series4ALF-200 LBF
Temperature Rating33 to 140 deg F
Warranty5 Years
Domestic/ImportDomestic
Country of OriginUS
Standards and ApprovalsApproved By The Foundation For Cross-Connection Control And Hydraulic Research At The University Of Southern California | ASSE 1015 | CSA B64.5 | FM Approved | IAPMO Certified | NSF 372 | UL Listed | cUL Listed | PROP65: Cancer and Reproductive Harm

Item Features

  • Easy maintenance
  • Snap-in check retainers
  • Low pressure loss as documented by an independent laboratory
  • Center stem guided TriForce check valves