DESCRIPTION
Taco®, PC705-2, Pump Mixing Control, Variable Speed, Series: PC, 1 Outdoor Air and 2 Supply Water Sensor, User Interface: LCD Display, 3 VA Contact, 24 V Power, 1 ft Lead Length, -30 to 200 deg F Sensing, 12 to 18, 14 to 22 AWG Wire, Screw Terminal Electrical Connections, Wall Mounting, 4-3/4 in H x 2-7/8 in W x 1-7/8 in D Dimensions
The Taco Mixing Control regulates the supply water temperature to a heating system by simultaneously controlling a boiler and the speed of an injection pump. Based on the outdoor air temperature, the PC705 continuously adjusts the boiler differential to optimize the firing cycles of the boiler, prevent large water temperature swings, and increase the efficiency of the system. As the heating load increases, the Mixing Control speeds up the injection circulator and as the load decreases it slows down the injection circulator. The updated Mixing Control has a liquid crystal display that clearly shows the speed of the variable speed injection pump. It also features warm weather shut down, a maximum supply water temperature setting, and a boiler sensor that can be connected in order to prevent corrosion in the boiler due to flue gas condensation.
Taco® PC705-2 PC Variable Speed Pump Mixing Control, 1 Outdoor Air and 2 Supply Water Sensor, LCD Display User Interface
CBPN: 307055
MPN:PC705-2
DESCRIPTION
Taco®, PC705-2, Pump Mixing Control, Variable Speed, Series: PC, 1 Outdoor Air and 2 Supply Water Sensor, User Interface: LCD Display, 3 VA Contact, 24 V Power, 1 ft Lead Length, -30 to 200 deg F Sensing, 12 to 18, 14 to 22 AWG Wire, Screw Terminal Electrical Connections, Wall Mounting, 4-3/4 in H x 2-7/8 in W x 1-7/8 in D Dimensions
The Taco Mixing Control regulates the supply water temperature to a heating system by simultaneously controlling a boiler and the speed of an injection pump. Based on the outdoor air temperature, the PC705 continuously adjusts the boiler differential to optimize the firing cycles of the boiler, prevent large water temperature swings, and increase the efficiency of the system. As the heating load increases, the Mixing Control speeds up the injection circulator and as the load decreases it slows down the injection circulator. The updated Mixing Control has a liquid crystal display that clearly shows the speed of the variable speed injection pump. It also features warm weather shut down, a maximum supply water temperature setting, and a boiler sensor that can be connected in order to prevent corrosion in the boiler due to flue gas condensation.
Specifications
Item Features
- 35 to 150 deg F mix start
- Automatic reset ratio calculation
- Microprocessor based control
- Outdoor Sensor M 2036 and 2 of Universal Sensor 071
- Warm weather shutdown
- Wiring harness plugs directly into any Taco exp control
- 1 Outdoor air and 2 supply water sensor type
- The 705 regulates the supply water temperature to a heating system by controlling a boiler and the speed of an injection pump
- Indoor use only and < 90% RH ambient conditions
- -60 to 32 deg F outdoor design temp
- Liquid crystal display for ease of monitoring and adjusting the control
- Optimizes the firing cycles of the boiler
- NTC thermistor, 10 kW at 77 deg F