Taco® i125T4R-1

Taco® i125T4R-1, I Series, 4-Way Mixing Valve, 1-1/4 in Nominal, FNPT End Style, 300 psi Max Pressure, 9.3 Cv Flo, Outdoor Reset Actuator

CBPN: 307037

MPN:i125T4R-1

Price:
$939.99 / EA

DESCRIPTION

Taco® i125T4R-1, Mixing Valves, Series: I Series, 1-1/4 in Nominal, Threaded End Style, 300 psi Pressure, 20 to 240 deg F at 135 deg ambient, 9.3 Cv Flow, Media: Water/Glycol, Outdoor Reset Actuator, 3-3/8 in Inlet to Outlet Length, 4-5/16 in H x 2-3/8 in W x 3-5/16 in D Dimensions

Taco® i125T4R-1, I Series, 4-Way Mixing Valve, 1-1/4 in Nominal, FNPT End Style, 300 psi Max Pressure, 9.3 Cv Flo, Outdoor Reset Actuator

CBPN: 307037

MPN:i125T4R-1

Price:
$939.99 / EA
 
Taco Comfort Solutions Logo

DESCRIPTION

Taco® i125T4R-1, Mixing Valves, Series: I Series, 1-1/4 in Nominal, Threaded End Style, 300 psi Pressure, 20 to 240 deg F at 135 deg ambient, 9.3 Cv Flow, Media: Water/Glycol, Outdoor Reset Actuator, 3-3/8 in Inlet to Outlet Length, 4-5/16 in H x 2-3/8 in W x 3-5/16 in D Dimensions

Specifications

Brand: Taco®
Weight: 3.5 lbs
Nominal Size: 1-1/4 in
End Style: FNPT
Pressure Rating: 300 psi
Flow Capacity: 9.3 Cv
Actuator Type: Outdoor Reset
Dimensions: 4-5/16 in H x 2-3/8 in W x 3-5/16 in D
Inlet to Outlet Length: 3-3/8 in
Manufacturer Name: Taco
Media: Water/Glycol
Series: I Series
Temperature Rating: 20 to 240 deg F at 135 deg ambient
Type: 4-Way Zone Valve
Includes: Outdoor Sensor and System Supply Sensor
Application: For Heating
Country of Origin: US

Item Features

  • 2-way Injection, 3-way or 4-way Mixing
  • Operates Off Constant Power or Relay End Switch
  • Ball Valve Design, High Cv
  • Manual Operation Button
  • Solid State Microprocessor Design
  • Compact Design
  • Easy, One-handed Actuator Removal
  • Plug-in Low Voltage Connections
  • Multi-Status LED Indicator Light
  • Fail Safe Mode
  • Selectable Maximum Supply Temperature(110 deg F, 130 deg F, 150 deg F, or Off )
  • Selectable Minimum Supply Temperature( 85 deg F, when Maximum supply temperature isset to 150 deg F or Off )
  • Adjustable Minimum Boiler Return Temperature (120 deg F, 135 deg F, or Off )
  • Warm Weather Shutdown (70 deg F or Off )
  • Adjustable Heating Curve (0.2-2.2 Reset Ratio)
  • Adjustable Setpoint Dial (80 deg F to 180 deg F)
  • Selectable 15 deg F Setback
  • Optional Boiler Protection (Set at 135 deg F)